G3DZ-F4PU DC12

G3DZ-F4PU DC12

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    终端继电器

  • 数据手册
  • 价格&库存
G3DZ-F4PU DC12 数据手册
New Product Terminal Relay G6D-F4PU/G3DZ-F4PU (Push-In Plus Technology) G6D-F4B/G3DZ-F4B (Screw Terminal) Model with Push-In Plus technology Added to Terminal Relays with Four-point Output Lineup G6D-F4B G3DZ-F4B G6D-F4PU G3DZ-F4PU • Realized 5 A rating by optimal designs for wide variety of applications (Push-In Plus technology). • Push-In Plus terminal enables work reduction and requires no retightening. • Short Bars (order separately) ensure easy common wiring and crossover wiring to adjacent terminal relays. • Double wire method enables branch wiring (Push-In Plus technology) • Each relay has independent coils and contacts for PLC output compatible (both NPN and PNP). • Mechanical Relay models and power MOS FET relay models For the most recent information on models that have been (for high frequency contact ratings) are available. certified for safety standards, refer to your OMRON website. • LED operation indicator, diode for coil surge absorption, and tools for Refer to Safety Precautions on page 12. easy removal of relays are included as standard equipment. • UL and CSA certification for standard models. VDE certification for Screws terminal, TÜV certification for Push-In Plus terminal. IP20 protection code for Push-In Plus models. Features (G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology)) Pursuing High Usability Slimmer Width Yet Larger Power Supply Capacity Short Bars enable common wiring Rated load: 3A Larger current capacity by approx. Easy common wiring with Short Bars Tools for removal LED operation indicator Rated load: 5A Slimmer width by approx. 30% 67% Independent circuit for PLC output in both NPN and PNP * Branch wiring with double wire method Wide Variety of Application Width: 31 mm G6D-F4B (Screw) Rated load: 5A Width: 31 mm G6D-F4PU (Push-In Plus technology) Width: 43 mm G6B-4BND (Screw) NEW Applicable to Various Number of I/O Points Short Hight for Installation in Narrow Spaces Operating panel of each device, etc. Connector terminal box, etc. G2RV-SR G6D-F4PU 1 point 4 point G2RV-SR G70V 8 point 16 point Control box, etc. * Value Design for Panel Our shared concept “Value Design for Panel” for the specifications of products used in control panels (hereinafter called “Value Design”) will create new value to your control panels. Combining multiple products that share the Value Design concept will further increase the value provided to control panels. 1 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B Ordering Information When your order, specify the rated voltage.  Main unit Model with Push-In Plus technology Mounted Relay type Contact form Model 12 VDC G6D-F4PU Mechanical Relay 24 VDC SPST x 4 (1NO x 4) 12 VDC G3DZ-F4PU Power MOS FET relay Operation coil ratings 24 VDC Model with Screw Terminal Mounted Relay type Contact form Model 12 VDC G6D-F4B Mechanical Relay models 24 VDC SPST x 4 (1NO x 4) 12 VDC G3DZ-F4B Power MOS FET relay Operation coil ratings 24 VDC  Accessories (Order Separately) zConnection socket (single sales available) G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology) Model Operation coil ratings 12 VDC P6DF-F4PU 24 VDC G6D-F4B/G3DZ-F4B (Models with Screw terminal) Model Operation coil ratings 12 VDC P6DF-F4B 24 VDC Note: 1. Connection socket P6DF-F4B as a single part is not certified by safety standards individually. 2. Single socket which does not mount a relay (with cover) . zShort Bar (G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology)) Pitch Applicable models Number of poles Color PYDN-7.75-020@ 2 7.75 mm G6D-F4PU G3DZ-F4PU P6DF-F4PU 3 4 20 Model*1 Red (R) Blue (S) Yellow (Y) PYDN-7.75-030@ PYDN-7.75-040@ PYDN-7.75-200@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. *1. Replace the box (@) in the model number with the code for the covering color. Selection of the box (@): R=Red, S=Blue, Y=Yellow zShort Bar (G6D-F4B/G3DZ-F4B (Model with Screw Terminal)) Applicable Terminal Relay Model G6D-F4B G3DZ-F4B 2 Model G6D-4-SB G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B zReplacement Relay (G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology)) Applicable Terminal Relay Model Model G6D-F4PU/G6D-F4B G6D-1A-ASI G3DZ-F4PU/G3DZ-F4B G3DZ-2R6PL Operation coil ratings 12 VDC 24 VDC 12 VDC 24 VDC zParts for DIN Track Mounting Appearance Model Type 1m PFP-100N 0.5 m PFP-50N DIN Tracks End Plate *1 PFP-M Spacer PFP-S *1. When mounting support rail, please use End Plate (Model PFP-M). 3 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B Ratings/Specifications  Ratings  Characteristics zRelay Specification Coil Ratings (per G6D Relay) Operation coil rating DC 12 24 Rated current (mA) Coil resistance (Ω) 18.7 10.5 720 2,880 Item Must operate voltage (V) Must release voltage (V) Max. voltage (V) 70% max.* 10% min. 130% Power consump tion (mW) Approx. 200 Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±20%. 2. Performance characteristic data are measured at a coil temperature of 23°C. 3. The maximum allowable voltage is the maximum value of the operating voltage for the relay coil operating power supply. There is no continuous allowance. 4. The rated current includes the terminal’s LED current. * The must operate voltage is 75% or less of the rated voltage if the relay is mounted in the upside down. Contact Ratings (per G6D Relay) G6D-F4PU (Model with Push-In Plus technology) Item G6D-F4PU (Model with Push-In Plus technology) Model Load Relay output Contact resistance *1 100 mΩ max. Operate time *2 10 ms max. Release time *2 10 ms max. Insulation resistance Dielectric strength 1,000 MΩ min. (at 500 VDC) Between coil and contacts Between contacts of the same polarity 750 VAC, 50/60 Hz for 1 min Shock resistance voltage (between coil and contacts) Vibration resistance Shock resistance 2,000 VAC, 50/60 Hz for 1 min 4,000 V (1.2 × 50 μs) Destruction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction 500 m/s2 Malfunction 100 m/s2 Mechanical 20,000,000 operations min. (switching frequency: 18,000 operations/hr) Electrical *2 70,000 operations min. (5 A at 250 VAC, resistive load) 70,000 operations min. (5 A at 30 VDC, resistive load) (at 1,800 switching frequencies/hr) Endurance Resistive load (cosφ = 1) Rated load 5 A at 250 VAC, 5 A at 30 VDC 10 mA at 5 VDC Rated carry current Failure rate P Level (reference value *3) 5A Max. switching voltage 250 VAC, 30 VDC Ambient operating temperature, Ambient storage temperature -25 to 55°C (with no icing) Ambient operating humidity 45% to 85% LED color Yellow Sealing IP20 Weight Approx. 95 g Max. switching current 5A Max. switching capacity (reference value) 1,250 VA, 150 W G6D-F4B (Model with Screw terminal) Item Load Resistive load (cosφ = 1) Rated load 3 A at 250 VAC, 3 A at 30 VDC Rated carry current 5A Max. switching voltage 250 VAC, 30 VDC Max. switching current 5A Max. switching capacity (reference value) 1,250 VA, 150 W Note: The data shown above are initial values. *1. Measurement condition: 1 A at 5 VDC *2. Ambient temperature condition: 23°C *3. This value is measured at 120 switching frequencies/min. G6D-F4B (Model with Screw terminal) Model Item Relay output Contact resistance *1 100 mΩ max. Operate time *2 10 ms max. Release time *2 10 ms max. Insulation resistance Dielectric strength Between coil and contacts Between contacts 750 VAC, 50/60 Hz for 1 min of the same polarity Shock resistance voltage (between coil and contacts) Vibration resistance Shock resistance 1,000 MΩ min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min 4,000 V (1.2 × 50 μs) Destruction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction 500 m/s2 Malfunction 100 m/s2 Mechanical 20,000,000 operations min. (switching frequency: 18,000 operations/hr) Electrical *2 200,000 operations min. (3 A at 250 VAC, resistive load) 200,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 switching frequencies/hr) Endurance Failure rate P Level (reference value *3) 10 mA at 5 VDC Ambient operating temperature, Ambient storage temperature -25 to 55°C (with no icing) Ambient operating humidity 45% to 85% LED color Yellow Sealing --- Weight Approx. 65 g Note: The data shown above are initial values. *1. Measurement condition: 1 A at 5 VDC *2. Ambient temperature condition: 23°C *3. This value is measured at 120 switching frequencies/min. 4 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B  Ratings  Characteristics zPower MOS FET Relay Specifications G3DZ-F4PU (Model with Push-In Plus technology) Model Input (per G3DZ Power MOS FET Relay) Item Rated voltage Operating voltage Must Must operate release voltage level voltage level Input impedance Rated current 12 9.6 to 14.4 VDC 9.6 VDC max. 2 kΩ ±20% 8.0 mA ±20% Power MOS FET relay output Must operate time 10 ms max. Release time 15 ms max. Output ON-resistance 2.4 Ω max. Leakage current at OFF state 10 μA max. (at 125 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Note: The rated current includes the terminal’s LED current. Dielectric strength between I/O 2,000 VAC, 50/60 Hz for 1 min Output (per G3DZ Power MOS FET Relay) Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance 500 m/s2 Ambient operating temperature, Ambient storage temperature -25 to 55°C (with no icing) Ambient operating humidity 45% to 85% LED color Yellow Sealing IP20 Weight Approx. 95 g DC 24 19.2 to 28.8 VDC Rated operating voltage 5 to 240 VAC 5 to 100 VDC 19.2 VDC max. Load voltage range 3 to 264 VAC 3 to 125 VDC 1 VDC min. 4 kΩ ±20% Load current 100 μ to 0.3 A Note: There is no output polarity for the G3DZ. 8.2 mA ±20% Inrush current resistance 6 A (10 ms) G3DZ-F4B (Model with Screw terminal) Model Item Power MOS FET relay output Must operate time 10 ms max. Release time 15 ms max. Output ON-resistance 2.4 Ω max. Leakage current at OFF state 10 μA max. (at 125 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength between I/O 2,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance 500 m/s2 Ambient operating temperature, Ambient storage temperature -25 to 55°C (with no icing) Ambient operating humidity 45% to 85% LED color Yellow Sealing --- Weight Approx. 65 g 5 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B  Ratings for Safety Standard Certification The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. G6D-F4PU/G3DZ-F4PU zUL-certified Models (File No. E41515) Model Standard number Category Listed/ Recognition Classification Operating coil ratings Number of poles Contact ratings Rated load voltage 250 VAC 30 VDC G6D-F4PU NRNT/7 Load Current, General Use and Resistive 5 A at 40°C Listed 12 VDC 24 VDC UL508 4 Rated load voltage 5-240 VAC 5-100 VDC G3DZ-F4PU Certified number of operations Mechanical 20,000,000 operations min. (at 18,000 switching frequencies/hr) Electrical 70,000 operations (5 A at 250 VAC, resistive load) 70,000 operations (5 A at 30 VDC, resistive load) (at 1,800 switching frequencies/hr) --- Load Current, General Use and Resistive 0.3 A at 55°C P6DF-F4PU SWIV2 Contact terminal 5 A, 250 V Recognition --- zCSA-certified Models (File No. LR35535) Model P6DF-F4PU Standard number Operating coil ratings Class number CLASS 3211 07 CLASS 3211 87 C22.2 NO. 14 12 VDC 24 VDC Number of poles 4 Contact ratings Contact terminal 5 A, 250 V zTÜV Rheinland Certification (Certification No.R50429253) Model G6D-F4PU Operating Coil ratings 12 VDC 24 VDC Number of poles 4 Contact ratings Rated load voltage 250 VAC 30 VDC Load Current, General Use and Resistive 5 A at 40°C Certified number of operations Mechanical 1,000,000 operations (at 18,000 switching frequencies/hr) Electrical 70,000 operations (5 A at 250 VAC, resistive load) 70,000 operations (5 A at 30 VDC, resistive load) (at 1,800 switching frequencies/hr) zTÜV Rheinland Certification (Certification No.R50429249) Model G3DZ-F4PU Operating Coil ratings 12 VDC 24 VDC Number of poles 4 Contact ratings Rated load voltage 5-240 VAC 5-100 VDC Certified number of operations --- Load Current, General Use and Resistive 0.3 A at 55°C zTÜV Rheinland Certification (Certification No.50429224) Model P6DF-F4PU 6 Operating Coil ratings 12 VDC 24 VDC Number of poles 4 Contact ratings Contact terminal 5 A, 250 V Certified number of operations --- Certified number of operations --- G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B zUL-certified Models (File No. E87929) Model Standard number Category Listed/ Recognition Classification Operating coil ratings Number of poles Contact ratings Rated load voltage 250 VAC 30 VDC G6D-F4B UL508 SWIV2 Recognition 12 VDC 24 VDC Certified number of operations --- Load Current 5 A, Resistive 4 Rated load voltage 3-264 VAC 3-125 VDC G3DZ-F4B --- Load Current 0.3 A zCSA-certified Models (File No. LR35535) Model Standard number Class number Operating coil ratings Number of poles Contact ratings Rated load voltage 250 VAC 30 VDC G6D-F4B CLASS 3211 07 CLASS 3211 87 C22.2 NO. 14 12 VDC 24 VDC G3DZ-F4B 4 Certified number of operations --- Load Current 5 A, Resistive Rated load voltage 3-264 VAC 3-125 VDC --- Load Current 0.3 A, Resistive zVDE Certification (Certification No.40017757) Model G6D-F4B Operating coil ratings 12 VDC 24 VDC Number of poles 4 Contact ratings Rated load voltage 250 VAC 24 VDC Certified number of operations --- Load Current 3A zVDE Certification (Certification No.40046252) Model G3DZ-F4B Operating coil ratings 12 VDC 24 VDC Number of poles 4 Contact ratings Rated load voltage 5-240 VAC 5-100 VDC Certified number of operations --- Load Current 0.3 A zVDE Certification (Certification No.40046241) Model P6DF-F4B Operating coil ratings 12 VDC 24 VDC Number of poles Contact ratings Certified number of operations Rated load voltage 250 VAC 4 --Load Current 0.3 A 7 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B Engineering Data  Engineering Data zG6D-F4PU Endurance Curve 100 Operation times (× 104 times) Switching current (A) Maximum Switching Capacity 50 30 10 5 3 DC resistive load AC resistive load 500 300 100 30 10 1 0.5 5 0.3 3 0.1 0 250 VAC, 30 VDC, Resistive load 50 3 5 10 30 50 100 250 500 250 VAC, 30 VDC, Inductive load (cosФ=0.4 L/R=7 ms) 0 1 2 3 4 5 6 7 8 9 10 Switching current (A) Switching voltage (V) 5 Load current (A) Load current (A) Load Current vs. Ambient Temperature Load Current vs. Ambient Temperature (Specifications with UL and TÜV (Product specification) certification) 4 5 4 3 3 2 2 1 1 0 -25 -20 0 20 40 55 60 80 0 -25-20 100 0 20 40 55 60 Ambient temperature (˚C) 80 100 Ambient temperature (˚C) zG6D-F4B 100 50 30 10 5 3 DC resistive load AC resistive load 100 50 250 VAC, 30 VDC, Resistive load 30 5 250 VAC, 30 VDC, Inductive load (cosФ=0.4 L/R=7 ms) 3 0.5 0.3 3 5 10 30 50 100 250 500 Switching voltage (V) 8 500 300 10 1 0.1 0 Endurance Curve Operation times (× 104 times) Switching current (A) Maximum Switching Capacity 0 1 2 3 4 5 6 7 8 9 10 Switching current (A) G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B zG3DZ-F4PU Load Current vs. Ambient Temperature Inrush current resistance 1 Inrush current (A.Peak) Load current (A) Non-repetitive (Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.) 0.8 0.6 0.4 10 8 6 4 0.3 0.2 0 -25 -20 2 0 20 40 55 60 80 0 100 5 10 30 50 100 Ambient temperature (˚C) 300 500 1,000 3,000 5,000 Energizing time (ms) Note: These data are actual measured values that were sampled from the production line and prepared in graph format, and are for reference purposes only. A relay is manufactured by mass production, and as a basic rule must be used with allowance made for a certain amount of deviation. zG3DZ-F4B Load Current vs. Ambient Temperature Inrush current resistance 1 Inrush current (A.Peak) Load current (A) Non-repetitive (Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.) 0.8 0.6 0.4 10 8 6 4 0.3 0.2 0 -25 -20 2 0 20 40 55 60 80 100 Ambient temperature (˚C) 0 5 10 30 50 100 300 500 1,000 3,000 5,000 Energizing time (ms) Note: These data are actual measured values that were sampled from the production line and prepared in graph format, and are for reference purposes only. A relay is manufactured by mass production, and as a basic rule must be used with allowance made for a certain amount of deviation. 9 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B Dimensions (Unit: mm)  Main unit G6D-F4PU G3DZ-F4PU LED operation indicator 2-4 dia. or 2-M3.5 IN side + 3 7 + 2 6 2 + 1 5 3 + 4 108±0.3 OUT side Tool for easy removal of relays Mounting Hole Dimensions 31 max. 30 33.6 35 max. Note: Pull out the hooks to mount the Relay with screws. Terminal Connection Examples + 4 8 + 3 7 + 2 6 1 5 12 11 10 9 16 15 14 13 L4 L3 L2 L1 12 11 10 9 16 15 14 13 Note: 1. Pay utmost attention not to make mistakes with the polarity of the input terminals. 2. There is no output polarity for G6D-F4PU/G3DZ-F4PU. + AC (DC power supply is also available.) Mounting Hole Dimensions LED operation indicator 16-M3 Phillips screw 2-4 dia. or 2-M3.5 8.7 4 3 2 1 8 7 6 5 IN 68 max. 2 1 3 + 3 7 + 2 6 + 1 5 + 1 2 3 4 OUT side 12 11 10 9 16 15 14 13 31 max. 35 max. 23±0.3 Tool for easy removal of relays Terminal Connection Examples + 8 76±0.3 8.7 8 4 4 RY1 RY2 RY3 RY4 4 Terminal Arrangement/Internal Connection Diagram (Top View) IN side OUT 10 8 1 90.4 max. 100 max. G6D-F4B G3DZ-F4B 4 3 7 + 2 6 + 1 5 12 11 10 9 16 15 14 13 L4 L3 L2 L1 + AC (DC power supply is also available.) 12 11 10 9 16 15 14 13 Note: 1. Pay utmost attention not to make mistakes with the polarity of the input terminals. 2. There is no output polarity for G6D-F4B/G3DZ-F4B. G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B  Accessories (Order Separately) zShort Bars PYDN-7.75-@@ (7.75 mm) Pitch L G6D-F4PU G3DZ-F4PU P6DF-F4PU 7.75 mm 18.5 12 2.25 Number of poles Applicable model L (Length) Color 3.90 2 15.1 3 22.85 4 30.6 20 154.6 Model* PYDN-7.75-020@ Red (R) Blue (S) Yellow (Y) PYDN-7.75-030@ PYDN-7.75-040@ PYDN-7.75-200@ * Replace the box (@) in the model number with the code for the covering color. Selection of the box (@): R=Red, S=Blue, Y=Yellow Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. 1.57 zShort Bars G6D-4-SB 7.62 7.62 7.62 5.7 3.7 5 9.6 (28.56) 2.6 zParts for DIN Track Mounting DIN Tracks PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 25 10 25 15 (5)* 1,000 (500)* End Plate PFP-M 27±0.15 1 * () indicates the dimension of PFP-50N. 10 6.2 M4 × 8 Pan head screw 1.8 1 50 35.5 35.3 1.8 11.5 10 M4 Spring washer Spacer PFP-S 1.3 4.8 16 12 5 34.8 44.3 16.5 11 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B Safety Precautions Be sure to read the Common Precautions for All Relays in the website. Warning Indications Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. Precautions for Safe Use zTransport • Do not transport the I/O Relay Terminal under the following locations. Doing so may occasionally result in damage, malfunction, or deterioration of performance characteristics. • Locations subject to water or oil • Locations subject to high temperature or high humidity • Locations subject to condensation as the result of rapid changes in temperature. • Do not transport a Socket when it is not packaged. Damage or failure may occur. zOperating and Storage Environments • Do not use or store the I/O Relay Terminal in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • Locations subject to rainwater or water splashes. • Locations subject to exposure to water, oil, or chemicals. • Locations subject to high temperature or high humidity. • Storage at locations subject to ambient temperatures outside the range -25 to 55°C • Usage at locations subject to ambient temperatures outside the range -25 to 55°C • Locations subject to relative humidity outside the range 45% to 85% • Locations subject to condensation as the result of rapid changes in temperature. • Locations subject to corrosive or flammable gases. • Locations subject to dust, salts, or iron, or locations where there is salt damage • Locations subject to direct sunlight. • Locations subject to shock or vibration. zInstallation and Mounting • Mount the I/O Relay Terminal in the specified direction. Otherwise excessive heat generated by the I/O Relay Terminal may occasionally cause burning. Mounting Directions • Mount the I/O Relay Terminal firmly to a DIN Track. Otherwise, the I/O Relay Terminal may fall off. • Do not handle the I/O Relay Terminal with oily or dusty (especially iron dust) hands. • Make sure that there is no excessive ambient temperature rise due to the heat generation of the I/O Relay Terminal. If the I/O Relay Terminal is mounted inside a panel, install a fan so that the interior of the panel is fully ventilated. 12 zInstallation and Wiring • Use wires that are suited to the load current and voltage. Otherwise, excessive heat generated by the wires may cause burning or may cause the wire covering to melt, possibly leading to electric shock. • Do not use wires with a damaged outer covering. it may result in electric shock or ground leakage.it may result in electric shock or ground leakage. • Do not wire any wiring in the same duct or conduit as power or high-tension lines. Inductive noise may damage the I/O Relay Terminal or cause it to malfunction. • Do not apply a voltage or current that exceeds the rating to any terminal. Doing so may result in failure or burning. • Do not use a deforming Short Bars. Doing so may result in damage, malfunction, or deterioration of performance characteristics. zPush-In Plus Terminal • Do not wire anything to the release holes. • Do not tilt or twist the screwdriver while it is inserted into a release hole on the terminal. The terminal may be damaged. • Insert a flat-blade screwdriver into the release holes at an angle. The terminal may be damaged if you insert the screwdriver straight in. • Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. • Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. • Do not insert more than one wire into each terminal insertion hole. • To prevent wire materials from smoking or ignition, confirm wire ratings and use the wiring materials given in the following table. Recommended wires 0.5 to 1.5 mm2/AWG20 to 16 Stripping length (Ferrules not used) 8 mm zApplication • Select a load within the rated values. Not doing so may result in malfunction, failure, or burning. • The G6D may occasionally rupture if short-circuit current flows. As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. • Use a power supply within the rated frequencies. Otherwise, malfunction, failure, or burning may occasionally occur. • Minor electrical shock may occasionally occur if you touch the power charging area such as the terminal wiring area. Always turn OFF the power supply before performing wiring. G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B • Insert Short Bars so that the protrusion part of a Short Bar comes to the wire insertion side. If the Short Bar is inserted in the upside down direction, the Short Bar may not be inserted securely. NG OK Precautions for Correct Use • Do not drop the Socket or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. • Use a power supply with low noise. z G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology) 1. Connecting Wires to the Push-In Plus Terminal Part Names of the Terminal Short bar insertion hole Release hole Terminal (insertion) hole Connecting Wires with Ferrules and Solid Wires Insert the solid wire or ferrule straight into the terminal until the end strikes the terminal. zRecommended Ferrules and Crimp Tools Recommended ferrules Applicable wire Stripping Recommended ferrules Ferrules length Conductor [mm] Manufactured Manufactured length Manufactured (Ferrules by Phoenix by (mm2) (AWG) (mm) by Wago used) Contact Weidmuller 0.25 0.34 24 22 0.5 20 0.75 18 1/1.25 18/17 1.25/1.5 17/16 8 10 AI0,25-8 10 12 AI0,25-10 8 10 AI0,34-8 10 12 AI0,34-10 H0.25/12 --H0.34/12 --- FE-0.25-8N-YE --FE-0.34-8N-TQ --- 8 10 AI0,5-8 H0.5/14 FE-0.5-8N-WH 10 12 AI0,5-10 H0.5/16 FE-0.5-10N-WH 8 10 AI0,75-8 H0.75/14 FE-0.75-8N-GY 10 12 AI0,75-10 H0.75/16 FE-0.75-10N-GY 10 AI1-8 H1.0/14 FE-1.0-8N-RD 10 12 AI1-10 H1.0/16 FE-1.0-10N-RD 8 10 AI1,5-8 H1.5/14 FE-1.5-8N-BK 10 12 AI1,5-10 H1.5/16 FE-1.5-10N-BK 8 Recommended crimp tool CRIMPFOX6 CRIMPFOX6T-F PZ6 roto CRIMPFOX10S Ferrules or solid wires • If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wire. Connecting Stranded Wires Use the following procedure to connect the wires to the terminal. 1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10° and 15°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole. 2. With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal. 3. Remove the flat-blade screwdriver from the release hole. (1) (3) Flat-blade screwdriver (3) (1) Variocrimp4 Note: 1. Make sure that the outer diameter of the wire coating is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. 2. Make sure that the ferrule processing dimensions conform to the following figures. 8 to 10 mm 1.9 mm max. Release hole Terminal (insertion) hole 2.6 mm max. 10° to 15° (2) (2) Stranded wires Checking Connections • After the insertion, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal. • To prevent short circuits, insert the stripped part of a stranded or solid wire or the conductor part of a ferrule until it is hidden inside the terminal insertion hole. • If you use recommended ferrules, part of the conductor may be visible after the ferrule is inserted into the terminal, but the product insulation distance will still be satisfied. 3. Wires of AWG24 to AWG22/0.25 mm2 to 0.34 mm2 are not certified by UL standard. 4. Do not connect a ferrule for the applicable wires (AWG17 to AWG16/1.25 mm2 to 1.5 mm2) with an adjacent terminal insertion hole. 13 G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B 2. Removing Wires from the Push-In Plus Terminal Use the following procedure to remove wires from the terminal. The same method is used to remove stranded wires, solid wires, and ferrules. 1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. 2. With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. 3. Remove the flat-blade screwdriver from the release hole. (1) (3) zRelay Replacement • Use the Relay Removal Tool provided with the Unit to dismount a Terminal Relay. • Always turn OFF the power supply before replacing Relays. • When mounting Relays, take care to vertically insert the sockets of relays into the contact pins properly. • Relays with other models or other voltages cannot be mounted together. Flat-blade screwdriver (3) (1) 10° to 15° (2) (2) Wire Recommended Flat-blade Screwdriver Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. The following table shows manufacturers and models as of 2018/Dec. Side Front 2.5 mm dia. Example: G6D-F4PU zRemoving the Terminal Cover (G6D-F4B) 0.4 mm Hold the base side of the terminal cover as shown in the diagram, and remove the terminal cover by pulling it in upward. 2.5 mm Model Manufacturer ESD 0,40×2,5 Wera SZS 0,4×2,5 SZF 0-0,4×2,5 * Phoenix Contact 0.4×2.5×75 302 Wiha AEF.2,5×75 Facom 210-719 Wago SDIS 0.4×2.5×75 Weidmuller 9900 (-2.5 × 75) Vessel * OMRON’s exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4×2,5 (manufactured by Phoenix Contact). zMountable Relays Relays and SSRs cannot be mounted together. 14 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2019 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_1_0319 Cat. No. J228-E1-01 0319(0319)
G3DZ-F4PU DC12 价格&库存

很抱歉,暂时无法提供与“G3DZ-F4PU DC12”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G3DZ-F4PU DC12
    •  国内价格
    • 1+674.39520
    • 200+260.98200
    • 500+251.81280
    • 1000+247.27680

    库存:0